00 81L 11PPPPI0090 000001 01Oventrop GmbH & Co. KG 28.03.24 000002 02OVENTROP GmbH & Co.KG - Online GAEB Export 000003 08EUR EURO 000004 11 1 N Titel 000005 12Leistungspositionen 000006 21 1 1 NNN 00000001000Stck 000007 25OVENTROP-Regudis W-HTE Electronic dwelling station 000008 26 The Regudis W-HTE dwelling station with 000009 26 factory-preassembled electronic control and copper 000010 26 brazed stainless steel plate heat exchanger enables 000011 26 the energy-efficient and hygienic supply of a 000012 26 dwelling with hot and cold potable water as well as 000013 26 heating water. 000014 26 000015 26 It is mounted on a thermally insulated lower shell 000016 26 for flush or surface wall mounting. The pipes are 000017 26 made of stainless steel 1.4404, the fittings of brass. 000018 26 An optional thermal insulation reduces heat 000019 26 dissipation and prevents heating of the cold water by 000020 26 separating the hot and cold pipes. Insertable 000021 26 elements integrated in the upper thermal insulation 000022 26 shell allow recesses for the water meter, the heat 000023 26 meter, as well as the heat exchanger to ensure rapid 000024 26 cooling of the heat exchanger after a tapping process. 000025 26 With the optional thermal insulation, the 000026 26 installation depth of 110 mm is not exceeded. All 000027 26 wetted parts on the potable water side are made of 000028 26 brass, stainless steel 1.4401 and 1.4404 and potable 000029 26 water approved plastics. 000030 26 000031 26 With an asymmetrical arrangement of the stainless 000032 26 steel plates of the heat exchanger, as well as a 000033 26 pressure loss-optimised design of the station, the 000034 26 station allows particularly efficient operation and 000035 26 enables hot water volume flows of 11-21 l/min 000036 26 (performance range 1) at excess temperatures of 0-15 000037 26 K (according to SPF test procedure). This means that 000038 26 discharge capacities and excess temperatures can be 000039 26 individually adapted to the existing system 000040 26 parameters. The low excess temperatures make the 000041 26 station particulary suitable for operation in low 000042 26 temperature systems. 000043 26 000044 26 The adaptive electronic control independently adjusts 000045 26 to the operating conditions in the overall system. 000046 26 The set potable water temperature is constantly 000047 26 controlled, regardless of system temperatures, 000048 26 pressure loss ratios and required draw-off qunatities. 000049 26 A demand-controlled priority circuit of the 000050 26 multifunctional control valve ensures intelligent 000051 26 energy distribution for hot potable water preparation 000052 26 as well as for the the heat supply of a residential 000053 26 unit. 000054 26 In heating mode, the integrated differential pressure 000055 26 control of the control valve ensures efficient heat 000056 26 distribution between the stations. Hydronic balancing 000057 26 in the pipe network to the station is therefore 000058 26 unnecessary. 000059 26 In the event of a power failure, a failsafe mode is 000060 26 activated. In failsafe mode, the actuator closes the 000061 26 control valve to prevent uncontrolled heating of the 000062 26 potable water. 000063 26 A status LED indicates the current operating status 000064 26 of the station. 000065 26 000066 26 The Regudis W-HTE basic station can be individually 000067 26 extended with the following functions in a 000068 26 time-saving manner my means of a modular plug and 000069 26 play assembly concept: 000070 26 Mixed heating circuit (flow temperature control 000071 26 module) Simultaneous supply of an unmixed and a 000072 26 mixed heating circuit (heating circuit connection 000073 26 fitting) Potable water circulation (potable water 000074 26 circulation module) Electrical reheating of the 000075 26 potable water (instantaneous water heater module) 000076 26 System separation of the heating circuit on the 000077 26 dwelling side from the heating circuit on the 000078 26 building side (Duo heating circuit separation module) 000079 26 000080 26 The Regudis W-HTE dwelling station consists of the 000081 26 following components: 000082 26 Connection box for power supply 230 V AC, rated 000083 26 current 50 mA, output voltage 5 V DC, rated output 000084 26 current 1200 mA, protection type IP 65, protection 000085 26 class II, overvoltage category III, ambient 000086 26 temperature 0-60 °C Actuator with integrated 000087 26 potable water temperature control 40-70 °C, max. 000088 26 ambient temperature 0-60 °C, power consumption 0.15-3 000089 26 W, protection type IP 54, input voltage 5 V DC 000090 26 Volume flow sensor (enables volume flow detection 000091 26 from 1 l/min) Vent valve in the heating circuit 000092 26 Multifunctional control valve for large flow rates 000093 26 with integrated differential pressure control valve 000094 26 and demand-controlled priority circuit for hot water 000095 26 preparation Drain valve in the primary circuit 000096 26 Zone valve for heating circuit control Drain valve 000097 26 in the heating circuit with strainer Copper brazed 000098 26 plate heat exchanger made of stainless steel 1.4401/1. 000099 26 4404 PT 1000 temperature sensor for hot water 000100 26 Connection for potable water circulation module G 1 000101 26 Spacer for heat meter G ?, 110 mm Spacer for water 000102 26 metrer G ?, 110 mm Connection for derivative 000103 26 temperature control set M 22 x 1 Filter insert in 000104 26 the primary supply Connection in the primary supply 000105 26 for the temperature sensor of the heat meter M 10 x 1. 000106 26 0 Performance data potable water: 000107 26 Hot water capacity heat exchanger: 30-58 kW 000108 26 (performance range 1) 000109 26 at 50-65 °C primary and 10 °C/50 °C secondary 000110 26 Draw-off quantity: 11-21 l/min (according to SPF test 000111 26 procedure) 000112 26 Pressure loss secondary: 350-1150 mbar (without cold 000113 26 water meter) 000114 26 3 ball valve connections DN 20 000115 26 000116 26 Performance data heating: 000117 26 Heating output: 14 kW, delta T 20 K 000118 26 max. 600 l/h 000119 26 Max. differential pressure: 2.0 bar 000120 26 Min. differential pressure: 150 mbar 000121 26 Pressure loss primary: 150-350 mbar (without heat 000122 26 meter) 000123 26 4 ball valve connections DN 20 000124 26 000125 26 General data: 000126 26 Max. operating pressure: 10 bar 000127 26 T max (primary): 90 °C 000128 26 Ambient temperature: 2-35 °C 000129 26 WxHxD (without ball valves): 600 x 455 x 110 mm 000130 26 Centre distance of the connections: 65 mm 000131 26 Centre distance to the wall: 26.5 mm 000132 26 Weight: 7.7 kg 000133 26 000134 26 Extensive accessories: 000135 26 Flow temperature control module for surface heating, 000136 26 heating circuit connection fitting, potable water 000137 26 circulation module, instantaneous water heater module, 000138 26 Duo heating circuit separation module, upper  000139 26 thermal insulation shell, derivative temperature 000140 26 control set, flushing and mounting bridge, earthing 000141 26 clamp, connection and shutoff set, flush-mounted 000142 26 cabinets, surface-mounted cabinets, revision frame, 000143 26 Regubox exclusive surface-mounted bonnet 000144 26 000145 26 000146 26 Nennweite: DN20 - 3/4 000147 26 Anschluss: Internal thread 000148 26 000149 26 Art.-Nr.: 1344030 000150 26 EAN-Code: 4026755446890 000151 26 Hersteller: OVENTROP GmbH & Co. KG, Olsberg 000152 26 Subject to technical changes. 000153 31 1 000154 99 00001000155