Logo Oventrop GmbH & Co. KG

OKF-CK22 Flat-plate collector


The OKF-CK22 flat-plate collectors can be used for hot potable water preparation, solar backup heating and swimming pool heating. They can be used in landscape or portrait format for on-roof installation or free-standing installation (flat roof installation). In-roof installation in portrait format is also possible.

The flat-plate collectors have a collector cover with matt anti-reflective glass for 96 % light transmission, a laser welded aluminium double harp absorber with copper pipe register for optimal energy yield and low pressure loss, a rear wall insulation and a circumferential frame insulation made of mineral wool and a UV-resistant EPDM glass seal.

Due to the high-quality materials used, the flat-plate collectors achieve a high degree of efficiency. In addition, they feature plug-in connections and pre-assembled rail systems and are therefore characterized by simple “plug and play” installation.
No longer produced
Art.No.: 1361340
EAN: 4026755416923
Výrobce: Oventrop GmbH & Co. KG
Subject to technical changes.

Rozměry

Rozměry výrobku

Délka Šířka Výška Hmotnost
1933 mm 1163 mm 110 mm 37 kg

Jednotky balení

Typ Množství Délka Šířka Výška Hmotnost
Lepenková krabice 1 1933 mm 1163 mm 110 mm 37 kg

Obrázky

Product images

  Velikost souboru
601,95 KB
  Velikost obrázku
6769 px x 6690 px
  Charakteristika
  •  Unikátní obrázek výrobku
  •  Samostatný
Download
  Velikost souboru
1,43 MB
  Velikost obrázku
6769 px x 6690 px
  Charakteristika
  •  Unikátní obrázek výrobku
  •  Samostatný
Download
  Velikost souboru
862,3 KB
  Velikost obrázku
2362 px x 2362 px
  Charakteristika
  •  Unikátní obrázek výrobku
  •  Samostatný
Download

Drawings

  Velikost souboru
16,1 KB
  Velikost obrázku
488 px x 487 px
  Charakteristika
  •  Unikátní obrázek výrobku
  •  Samostatný
Download

Dokumentace

Brožura

  Jméno Velikost souboru
more languages 1,41 MB
more languages 5,2 MB

ETIM

Klassifizierung
ETIM 7.0
Property Value
Collector efficiency 67 %
1st order heat loss coefficient (a1) 3.55 W/(m².K)
2nd order heat loss coefficient (a2) 0.015 W/(m².K²)
Incidence angle modifier (IAM) 0.94
Outer pipe diameter, all connections 18 mm
Collector surface area 2.01 m²
Yield according to DST test 0.833 GJ/year
Position of collector at façade
Position of collector in pitched roof
Position of collector on pitched roof
Position of collector on flat roof
Collector set-up, portrait
Collector set-up, landscape
Length of collector 1933 mm
Width, collector 1163 mm
Height, collector 110 mm
Connections Other
Max. allowable operating pressure 10 bar
Collector principle Flat panel
Glycol-resistant
Suitable for closed system
Suitable for swimming pool water heating
Thermal tape