Language
Memory list
Toggle navigation
Go
Company profile
Company
Works
International Presence
Production and Quality
Innovation and Design
Product ranges
System competence
Oventrop Service
History
Career
Jobs at Oventrop
References
News
News
Videos
Topics
Hydronic Balancing
Videos
Introduction
Automatic hydronic balancing
Balancing of cooling systems
Software
Energy savings up to 20%
Comfortable indoor climate
Potable water hygiene
Potable water hygiene
OVplan
Regumaq X fresh water stations
Award winning design
Label for heating systems
ErP Label for heating systems
Software OVe.r.p.
Products
Item search
Product groups
Technical information / Operating instructions
Brochures
Online layout
Memory list
Regumat layout
Catalogue
Software
CAD / BIM (3D)
OVe.r.p.
OVplan
OVselect
OVsol
Oventrop App
Online solar calculation
Measuring systems
EIB / LON
Addresses
Worldwide
Subsidiaries
myOV
Registration data forgotten
Login / Register
Service
Support
Portal / Online access
Welcome!
In order to provide you with the best possible service, we use cookies on this website.
The cookies we use can be divided into different groups.
You can adjust your consent to the use of these cookies directly here, or at any time via the item "Privacy".
By clicking on “Accept all”, you consent to our use of cross-website tools to provide you with personalised information for marketing purposes, including outside our website through our partners. These tools enable personalised online ads and advanced analytics and reporting on audience and user behaviour. You also agree that the data may also be transferred to third countries outside the European Economic Area without an adequate level of protection under data protection law (in particular the USA). There are no guarantees that government agencies will not access your data. You can revoke this consent at any time with effect for the future here.
Necessary cookies
Cookies of this group are necessary for the proper operation of the website. They are not subject to consent and cannot be deactivated. By using our website, you agree to this.
Comfort cookies
Our website uses external services in some places to provide you with additional functions. This group includes, for example, our interactive representative card.
Marketing / Tracking cookies
These types of cookies allow us to determine, among other things, which content you are particularly interested in. In this way we can further expand our service for you and constantly improve our website.
Accept all
Save selection
Personalize settings
SystemCentre
Home
Service
SystemCentre
Support
Portal / Online access
Smart Home, centralised building control systems and other electronic controls
Limitation of flow
Double regulating- and isolating valve, female thread, bronze
Double regulating- and isolating valve, male thread, DZR
Double regulating valve flanged model, cast iron
Print version
No.
Article
Oventrop
Item no.
Qty.
To memory list
1
Double regulating and commissioning valve "Hydrocontrol VTR" PN 25bronze, both ports female, with blind plugs, DN 10
Double regulating and commissioning valve "Hydrocontrol VTR" PN 25bronze, both ports female, with blind plugs, DN 15
Double regulating and commissioning valve "Hydrocontrol VTR" PN 25bronze, both ports female, with blind plugs, DN 20
Double regulating and commissioning valve "Hydrocontrol VTR" PN 25bronze, both ports female, with blind plugs, DN 25
Double regulating and commissioning valve "Hydrocontrol VTR" PN 25bronze, both ports female, with blind plugs, DN 32
Double regulating and commissioning valve "Hydrocontrol VTR" PN 25bronze, both ports female, with blind plugs, DN 40
Double regulating and commissioning valve "Hydrocontrol VTR" PN 25bronze, both ports female, with blind plugs, DN 50
1060103
2
Isolating and orifice valve "Hydrocontrol ATR" PN 25bronze, both ports female, with blind plugs, DN 10
Isolating and orifice valve "Hydrocontrol ATR" PN 25bronze, both ports female, with blind plugs, DN 15
Isolating and orifice valve "Hydrocontrol ATR" PN 25bronze, both ports female, with blind plugs, DN 20
Isolating and orifice valve "Hydrocontrol ATR" PN 25bronze, both ports female, with blind plugs, DN 25
Isolating and orifice valve "Hydrocontrol ATR" PN 25bronze, both ports female, with blind plugs, DN 32
Isolating and orifice valve "Hydrocontrol ATR" PN 25bronze, both ports female, with blind plugs, DN 40
Isolating and orifice valve "Hydrocontrol ATR" PN 25bronze, both ports female, with blind plugs, DN 50
1067503
3
Double regulating and commissioning valve "Hycocon VTZ" PN 16DZR brass, pressure test points and drain valves, DN 15, G ¾ male
Double regulating and commissioning valve "Hycocon VTZ" PN 16DZR brass, pressure test points and drain valves, DN 20, G 1 male
Double regulating and commissioning valve "Hycocon VTZ" PN 16DZR brass, pressure test points and drain valves, DN 25, G 1¼ male
Double regulating and commissioning valve "Hycocon VTZ" PN 16DZR brass, pressure test points and drain valves, DN 32, G 1½ male
Double regulating and commissioning valve "Hycocon VTZ" PN 16DZR brass, pressure test points and drain valves, DN 40, G 11¾ male
1061804
4
Isolating and orifice valve "Hycocon ATZ" PN 16DZR brass, with pressure test points and drain valves, DN 15, G ¾ male
Isolating and orifice valve "Hycocon ATZ" PN 16DZR brass, with pressure test points and drain valves, DN DN 20, G 1 male
Isolating and orifice valve "Hycocon ATZ" PN 16DZR brass, with pressure test points and drain valves, DN 25, G 1¼ male
Isolating and orifice valve "Hycocon ATZ" PN 16DZR brass, with pressure test points and drain valves, DN 32, G 1½ male
Isolating and orifice valve "Hycocon ATZ" PN 16DZR brass, with pressure test points and drain valves, DN 40, G 1¾ male
1067404
5
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 20
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 25
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 32
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 40
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 50
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 65
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 80
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 100
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 125
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 150
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 250
Double regulating and commissioning valve "Hydrocontrol VFC" PN 16cast iron, flanges according to DIN, 2 pressure test points, DN 300
1062646
6
Set 1 = 1 fill and drain ball valvefor valves with "classic" measuring technique
1060191
7
Set 2 = 2 pressure test pointsfor valves with "classic" measuring technique
1060281
8
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 5 = 2 weldable tailpipes for valve DN 15, steel
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 5 = 2 weldable tailpipes for valve DN 20, steel
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 5 = 2 weldable tailpipes for valve DN 25, steel
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 5 = 2 weldable tailpipes for valve DN 32, steel
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 5 = 2 weldable tailpipes for valve DN 40, steel
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 6 = 2 solder tailpipes 18 mm for valve DN 15, brass
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 6 = 2 solder tailpipes 15 mm for valve DN 15, brass
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 6 = 2 solder tailpipes 18 mm for valve DN 20, brass
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 6 = 2 solder tailpipes 22 mm for valve DN 20, brass
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 6 = 2 solder tailpipes 28 mm for valve DN 25, brass
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 6 = 2 solder tailpipes 35 mm for valve DN 32, brass
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 6 = 2 solder tailpipes 42 mm for valve DN 40, brass
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 7 = 2 tailpipes with male thread, R ½ for valve DN 15
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 7 = 2 tailpipes with male thread, R ¾ for valve DN 20
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 7 = 2 tailpipes with male thread, R 1 for valve DN 25
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 7 = 2 tailpipes with male thread, R 1¼ for valve DN 32
Tailpipe sets for "Hycocon/Hydrocontrol/Hydromat"Set no. 7 = 2 tailpipes with male thread, R 1½ for valve DN 40
1060592
9
Insulation shellsfor "Hydrocontrol VTR/VPR/ATR/APR", "Hydromat QTR/DTR", "Aquastrom F/KFR", DN 15
Insulation shellsfor "Hydrocontrol VTR/VPR/ATR/APR", "Hydromat QTR/DTR", "Aquastrom F/KFR", DN 20
Insulation shellsfor "Hydrocontrol VTR/VPR/ATR/APR", "Hydromat QTR/DTR", "Aquastrom F/KFR", DN 25
Insulation shellsfor "Hydrocontrol VTR/VPR/ATR/APR", "Hydromat QTR/DTR", "Aquastrom F/KFR", DN 32
Insulation shellsfor "Hydrocontrol VTR/VPR/ATR/APR", "Hydromat QTR/DTR", "Aquastrom F/KFR", DN 40
Insulation shellsfor "Hydrocontrol VTR/VPR/ATR/APR", "Hydromat QTR/DTR", "Aquastrom F/KFR", DN 50
1060081
10
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 73.0 mm, 2 pressure test points, DN 65
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 88.9 mm, 2 pressure test points, DN 80
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 114.3 mm, 2 pressure test points, DN 100
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 141.3 mm, 2 pressure test points, DN 125
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 168.3 mm, 2 pressure test points, DN 150
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 219.1 mm, 2 pressure test points, DN 200
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 273.0 mm, 2 pressure test points, DN 250
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 323.9 mm, 2 pressure test points, DN 300
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 76.1 mm, 2 pressure test points, DN 65
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 139.7 mm, 2 pressure test points, DN 125
Double regulating and commissioning valve "Hydrocontrol VGC" PN 25cast iron, groove connection 165.1 mm, 2 pressure test points, DN 150
1063051
11
Insulation shellsfor "Hydrocontrol VFC/VFR/VFN/VGC/AFC", DN 20
Insulation shellsfor "Hydrocontrol VFC/VFR/VFN/VGC/AFC", DN 25
Insulation shellsfor "Hydrocontrol VFC/VFR/VFN/VGC/AFC", DN 32
Insulation shellsfor "Hydrocontrol VFC/VFR/VFN/VGC/AFC", DN 40
Insulation shellsfor "Hydrocontrol VFC/VFR/VFN/VGC/AFC", DN 50
Insulation shellsfor "Hydrocontrol VFC/VFR/VFN/VGC/AFC", DN 65
Insulation shellsfor "Hydrocontrol VFC/VFR/VFN/VGC/AFC", DN 80
Insulation shellsfor "Hydrocontrol VFC/VFR/VFN/VGC/AFC", DN 100
Insulation shellsfor "Hydrocontrol VFC/VFR/VFN/VGC/AFC", DN 125
Insulation shellsfor "Hydrocontrol VFC/VFR/VFN/VGC/AFC", DN 150
1062581